Technical

Data & test results

Independent test data and documentation for KOVON architectural film. All figures are drawn from third-party testing; full reports are available to specifiers on request.

Reaction to fire

B — s1, d0

BS EN 13501-1:2018

KOVON Grain — Performance Grain

Class B-s1,d0 means very low flame spread, the lowest smoke classification, and no flaming droplets.

Fire classification to BS EN 13501-1:2018, tested by SGS under HOKLAS accreditation (Reg. No. 229)

EN 13501-1 test results

Every measured parameter is within the Class B / s1 / d0 limits.

ParameterResultRequirement
FIGRA 0.2MJ18.5 W/s≤ 120 W/s
FIGRA 0.4MJ18.5 W/s≤ 120 W/s
THR 600s0.4 MJ≤ 7.5 MJ
SMOGRA (smoke)1.9 m²/s²≤ 30 m²/s² — s1
TSP 600s (smoke)38.7 m²≤ 50 m² — s1
Lateral flame spreadNone to edgeMust not reach edge
Flaming droplets / particlesNoned0
Ignitability — Fs (EN ISO 11925-2)≤ 150 mm / 60 sPass

Result applies to the tested build-up: 0.2 mm film (240 g/m²) self-adhered to a 10 mm A2 calcium silicate board, without joints. Valid for all A1/A2 substrates. The official SGS classification report (No. SDFTS26003552R01) was issued in July 2026 and is available to specifiers on request.

Material data

Properties & test data

Confirmed material properties and independent test results for the KOVON film.

CategoryStatusNotes
MaterialConfirmedPVC architectural decorative film, self-adhesive
Film thicknessConfirmed0.15–0.60 mm by design (excl. liner)
Area densityConfirmed240 g/m²
Substrate compatibilityConfirmedMDF · plywood · wood · stainless steel · aluminium · glass · painted surfaces
Installation temperatureConfirmedRecommended 18–25°C · working range 12–35°C
ApplicationConfirmedSelf-adhesive, seamless — suitable for flat and gently curved profiles
Adhesion (ISO 29862)ConfirmedStrong, professional-grade bond — independently tested
Abrasion resistance (ISO 9352, Taber CS-17)ConfirmedIndependently tested — engineered for high-traffic interiors
Roll sizeConfirmed1.22 m × 50 m, all series
Shelf lifeConfirmed2 years from production date; store below 38 °C, upright, away from sunlight and moisture
EN 16516 VOC emissionsIn ProgressTesting in progress — data available on request as results confirm

Application

Installation & handling

A summary of the KOVON installation guide and technical notes. The full illustrated guide is included in the product catalogue and available on request.

Installation guide

  1. Application scope

    Designed for interior surfaces, installed by trained professionals.

  2. Installation environment

    Install at 18–25°C on a completely dry substrate, in a clean, dust-free area.

  3. Substrate requirements

    Clean, smooth, stable surfaces — MDF, plywood, wood, metal, glass, painted surfaces.

  4. Surface preparation

    Sand, fill uneven areas, clean with alcohol, and dry fully before application.

  5. Primer treatment

    Apply 2–3 coats to cut edges, porous substrates, corners, and joints.

  6. Installation method

    Apply from the centre outward with a felt squeegee; use heat for curves, avoid overstretching.

  7. Joint & pattern

    Keep a consistent direction and batch; pre-check pattern alignment before installing.

Precautions & technical notes

  • Moisture & humidity

    Avoid moisture-prone substrates; seal edges properly in wet areas.

  • High temperature

    Avoid continuous heat above 50°C and direct sunlight.

  • Substrate limitations

    Not for uneven, unstable, or moving substrates — the base must be firmly fixed.

  • Inspection & batch control

    Inspect before installation; avoid mixing batches on the same surface.

  • Embossed / textured films

    Textured films need stronger pressure for full adhesion in recessed areas.

  • Mock-up first

    Always conduct a mock-up test before full installation.

Recommended tools
Felt squeegeeCutterHeat gun (optional)RollerMeasuring tapeCleaning cloth
This is a summary — the full illustrated installation guide with technical notes is available on request.

Installation should be carried out by trained professionals. Product performance may vary depending on substrate and site conditions — always conduct a mock-up test before full installation.

Compliance

Certification status

We report certification status transparently. Where a standard is still in progress, we say so — and provide the underlying test data on request.

Completed Testing
  • EN 13501-1 reaction to fire — Class B-s1,d0 (Performance Grain system, SGS report issued July 2026)
  • Strong, professional-grade adhesion (ISO 29862)
  • Abrasion resistant (ISO 9352, Taber CS-17)
In Progress
  • EN 16516 VOC emissions testing
Available Upon Request
  • EN 13501-1 reaction-to-fire classification report (Performance Grain system)
  • Adhesion test report (ISO 29862)
  • Abrasion test report (ISO 9352)
  • Substrate preparation & application guidelines

Documentation

Documents

The brochure, catalogue and installation guide download directly. Remaining documents are issued on request — tap to ask via WhatsApp.

KOVON Product Brochure (KOVON-BRO-2026-R1)

Full overview of the five KOVON series — Essence, Grain, Mineral, Atelier, and Metal — with colours and finishes.

PDF · 6 pages · 1.3 MB

Download PDF
KOVON Catalogue (KOVON-CAT-2026-R1)

The complete design catalogue — 400+ designs across five series, with codes and finishes for specification.

PDF · 68 pages · 26 MB

Download PDF
Technical Data Sheet — General (KOVON-TDS-2026-R1)

Material specification, substrate compatibility, application guidance, and confirmed test data.

Request Document
Technical Data Sheet — Performance Grain Fire-Rated System (KOVON-TDS-PG-2026-R1)

Reaction-to-fire classification to BS EN 13501-1:2018 for the Class B-s1,d0 result, tested by SGS under HOKLAS accreditation, including substrate scope. Official classification report No. SDFTS26003552R01 available on request.

Request Document
Test Performance Summary (KOVON-TSR-2026-R1)

Summary of confirmed test data for the KOVON film — adhesion (ISO 29862), abrasion resistance (ISO 9352), and reaction to fire (EN 13501-1).

Request Document
Installation Guide (KOVON-ING-2026-R1)

Full illustrated installation guide and technical notes — surface preparation, primer, application method, joints, handling, and recommended tools.

PDF · 273 KB

Download PDF
Sample Request

Request physical swatch samples for specification and client presentation.

Request Document

Test results relate to the configurations and substrates stated and may not apply to other build-ups. Always confirm project-specific compliance with a qualified fire engineer or specifier. Tectara Materials Limited is a materials supplier; installation is the responsibility of the appointed contractor.